A lead-acid battery pack is composed of multiple single-cell batteries connected in series, with each cell having a voltage of approximately 2V. Therefore, there are two common battery voltages: 6V and 12V. The core components of a battery pack include plates, separators, electrolyte, and casing. The electrode plate is made of lead antimony alloy, and the separator is used to prevent short circuits caused by contact between the positive and negative electrodes. The electrolyte is a mixture of pure sulfuric acid and distilled water. The casing is used to encapsulate the electrolyte and plates, maintaining the integrity of the battery.
Maintenance and upkeep methods
1. Electrolyte management: Strictly control the electrolyte density within the range of 1.24-1.28g/cm ³, and keep the liquid level 10-15mm above the electrode plate. When the density deviation of a single cell battery exceeds 0.05g/cm ³, balanced charging must be carried out to extend the life of the battery pack
2. Charging curve control: Adopting a three-stage charging strategy: fast charging during the constant current stage, precise control of gas evolution reaction during the constant voltage stage, and fine energy compensation during the float charging stage. This scientific charging method can increase the charging efficiency to 92% while controlling the water loss rate
3. Temperature monitoring: When the battery temperature exceeds 45 ℃, the intelligent system will automatically adjust the charging parameters to avoid the risk of thermal runaway
Product Photo Views: